The deadly truth about asbestos in New Zealand
To create efficient and environmentally responsible workspaces, Hynds Group engaged ACSL to design, build and install HVAC systems across new sites in Lower Hutt and Timaru, and its Auckland Head Office refurbishment.
Hynds Group, New Zealand’s leading water and wastewater management solutions supplier, exemplifies sustainability and innovation in their operations.
With new sites established in Wellington and Timaru, and a refresh of its Auckland Head Office, it was crucial for the HVAC systems to stand up to its reputation – one that focuses on sustainability and environmental responsibility.
ACSL was engaged for each project from concept to completion, designing, building and installing the HVAC systems. Based on ACSL’s expert recommendations, Mitsubishi Electric R32 Hybrid and Lossnay Fresh Air Heat Recovery Ventilation systems were implemented. These systems were chosen for their ability to align with Hynds’ sustainability goals, exemplifying their commitment to reducing emissions and creating environmentally responsible workspaces.
A HOLISTIC APPROACH TO SUSTAINABILITY
Hynds is focused on reducing emissions across all aspects of its operations, including direct emissions from its facilities, energy use, and the broader impacts of its supply chain and product lifecycle.
By adopting the Mitsubishi Electric R32 Hybrid VRF System and Lossnay Fresh Air Energy Recovery Ventilation System, as recommended by ACSL, Hynds aligns its efforts with the Science-Based Targets initiative (SBTi) to limit global warming to 1.5ºC. These systems will also be instrumental in helping Hynds achieve the ambitious goal of reducing Scope 1 and 2 emissions by 42 per cent by 2032.
Complemented by the Lossnay Fresh Air Energy Recovery Ventilation system, up to 85 per cent of heat energy from expelled air is recovered. This process pre-warms or pre-cools incoming fresh air, significantly reducing the load on air conditioning systems, improving air quality and maintaining balanced humidity levels.
A FOCUS ON TEAM SAFETY AND COMFORT
As a responsible PCBU (Person Conducting a Business or Undertaking), Hynds placed employee wellbeing at the forefront of its decision-making. Following ACSL’s guidance, it was ensured that the selected HVAC system met compliance with New Zealand safety standards while delivering superior comfort.
The R32 Hybrid System stood out due to its innovative design, which uses water as the primary heat exchange medium instead of refrigerants in occupied spaces. This reduces the risks associated with flammable refrigerants, ensuring compliance with AS/NZS 5149 safety standards.
The R32 Hybrid system’s water-based design also plays a role in enhancing comfort for Hynds staff. Water as a heat transfer medium provides milder supply air temperatures and significantly reduces drafts, creating a more pleasant indoor environment.
Water-based systems also offer superior control compared to refrigerant-based alternatives, particularly during part-load operations, which occur most of the time. This ensures more precise and consistent temperature regulation, contributing to an overall improved experience for building occupants.
MINIMAL ENVIRONMENTAL IMPACT
Specifying a HVAC system that would minimise environmental impact while adhering to Hynds’ sustainability goals was key to this project. This led to the adoption of a solution utilising a new-generation refrigerant with a significantly lower Global Warming Potential (GWP) compared to older alternatives. Equally important was choosing a system that required the smallest possible amount of refrigerant, further reducing its environmental footprint.
While many systems on the market still rely on older refrigerants with high GWP ratings, newer options, though more environmentally friendly, often present safety challenges due to their flammability. These considerations made finding a suitable system both essential and complex. The R32 Hybrid System met the requirements by:
- Using R32 refrigerant with a Global Warming Potential (GWP) of 675, significantly lower than traditional refrigerants with ratings up to 2,090.
- Requiring approximately half the refrigerant volume of traditional systems.
In particular, the Lower Hutt site has seen a fivefold reduction in potential refrigerant emissions, with 16 tonnes of CO2 compared to 89 tonnes seen with traditional systems (calculated based on Lower Hutt site using R410A VRF). The system’s water-based design also enhances energy efficiency, precisely matching capacity to the building’s requirements and reducing waste.
Further cost-savings include:
- The R32 Hybrid System’s water-based design offers an adaptable and efficient solution. Water enables precise flow adjustments, delivering the exact cooling or heating required and reducing energy waste. Since air conditioning systems usually operate at part capacity, the system’s precision results in consistent efficiency and real-world savings.
- The Hybrid System also avoids the need for costly refrigerant leakage sensors, which are usually required for systems using newer flammable refrigerants. At the Naenae Lower Hutt site, these sensors alone would have added approximately $5,000 annually for calibration and $10,000 every three years for replacement, totalling over $100,000 across 15 years. By eliminating this expense, the Hybrid System reduces maintenance demands and long-term operating costs.
To optimise energy use and operational efficiency, the AE-200E controller was installed. It allows precise temperature management, scheduling, and multi-unit control. This ensures the HVAC system operates only during business hours, reducing unnecessary energy consumption while maintaining a comfortable indoor environment.
The water-based architecture of the R32 Hybrid System ensures adaptability to evolving refrigerant technologies. Only limited refrigerant components require replacement during future upgrades, while the water components remain intact. This design contrasts with traditional systems, which would require full replacement, including pipework, when refrigerants change. This adaptability reduces long-term costs for Hynds and ensures the system’s continued relevance in a changing regulatory landscape.
Sensor, calibration and replacement pricing calculated based on available market information as at May 2025.
These Mitsubishi Electric HVAC solutions, implemented and recommended by ACSL, deliver a safe, efficiency, and environmentally friendly workplace with stable, quiet operation, consistent temperatures, and fresh air – creating a comfortable environment where employees can thrive.