About CCCANZ

Governance

Our People

Strategic Plan

Appointments

Membership

Buying Power

Standards Library

Find A Company

Business Support

Resources

Consumers

Course Catalogue

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About Irhace

Appointments

Committees

Governance

Our People

Strategic Plan

Membership

Professional Development

Awards

Careers

Find A Professional

Education

Member Login

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About RLNZ

Our People

Governance

Privacy Policy

Strategic Plan

Approved Filler

New or Renew

Approved Filler

Approved Filler Search

Resources

Consumers

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

HVAC&R HUB

BuildNZ

Summit 2027

HVAC&R SOUTH

SouthMACH

HVAC&R WAVE

Join the Wave

Wallie Askew

How to Enter

Rules of Competition

Previous Finalists

Competition judges

WORLDSKILLS

Worldskills NZ

FIND A PROFESSIONAL

PROFESSIONAL DEVELOPMENT

CAREERS IN HVAC&R

FIND A COMPANY

BULLETINS

FACT SHEETS

GUIDELINES

COURSE CATALOGUE

REFRIGERANT RECOVERY

APPROVED FILLER SEARCH

Training Newsletter

MEDIA

INDUSTRY JOURNAL 

MEDIA KIT

INFORMATION

INDUSTRY JOURNAL

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

STANDARDS LIBRARY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

IRHACE

CAREERS IN HVAC&R

PROFESSIONAL DEVELOPMENT

COURSE CATALOGUE

CCCANZ

BUYING POWER

RESOURCES

STANDARDS

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

OUR PEOPLE

AWARDS

APPOINTMENTS

MEMBER LOGIN

MEDIA

INDUSTRY JOURNAL

INDUSTRY DIRECTORY

MEDIA KIT

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

REFRIGERANT RECOVERY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

A guide to seismic non-structural elements for building services

Prashant Patel shares his knowledge in achieving NSE for buildings in New Zealand.

Words by Prashant Patel, M.IRHACE

The structure of any building in New Zealand is governed by the Building Act and NZ Building Code B1 – Structure. We have our own NZ Standard 1170 – Structural Design Actions, particularly part 5: 2004 which outlines the Earthquake Actions – New Zealand. The main reason to refer to these standards is to determine the Ultimate Limit State (Eu) and Serviceability Limit State (Es).

When touching on the non-seismic elements (NSE) of a structure system, it falls under NZS 4219:2009

– Seismic Performance of Engineering Systems in Buildings. This standard is for specific design of the NSE of the structure elements. However, it doesn’t cover all types of fire and mechanical services. Such as but not limited to:

1. Fire Sprinkler System

2. Suspended Ceilings

This standard is freely available on the Standards New Zealand website. I strongly recommend all service contractors to read through this standard as it provides some great examples and thresholds regarding seismic bracings.

These are just some of the examples and they have their own standards to comply with the NZBC B1 and the NSE of any structure in New Zealand.

As per NZS 4219:2009, there are two pathways to achieve NSE for any type of building,

1. SPECIFIC DESIGN METHOD

Such designs are drafted by experienced structural engineers such as CPEng as most of them fall under either AS or VM of the NZBC B1. These types of design could have generic approaches on the NSE components from the experience of the registered engineer.

2. NON-SPECIFIC DESIGN METHOD

Such designs could be done by NSE specialists as well as by the building services engineers such as Mechanical Engineer or Fire Engineer. Most of the NSE designs out there are done this way, determining the different parameters of the building and finally calculating the required restraint forces for all of the NSE components in question.

Guidance has been provided by BRANZ on the responsibilities associated with the producer statements. (See table on right.)

Considering the table, a contractor or building services engineer other than a Structure or Seismic NSE engineer, can also supply their own design along with Producer Statement 1 and can get a CPEng seismic engineer to review and supply a Producer Statement 2. Each contractor must issue their own Producer Statement 3 for the services they installed for any given project.

NZS 4219:2009 outlines some rules of thumbs when it comes to the Mechanical Services. Some of the main ones are as follows:

Rigid ductwork, where the hanger length from the top of the duct to the structural support exceeds 200 mm, shall be restrained against seismic forces determined in accordance with this Standard.

Flexible ductwork greater than 1.5 m in length shall be restrained in accordance with this clause.

Ducting not requiring restraint shall be installed with a clearance of 150 mm from hangers and braces for suspended ceiling systems or other adjacent suspended components.

Suspended components that are installed in line with the duct system and have an operating weight greater than 10 kg, such as fans, heat exchangers and humidifiers, shall be supported and laterally braced independently of the duct system.

Registers and grilles shall have positive fixings to the ducting. Ducting between ceiling mounted grilles and rigidly mounted ducting shall be flexible, or movement provision provided. Dampers, louvres and diffusers shall be positively attached to the duct with mechanical fasteners. Duct tape shall not be used to provide mechanical fixing or seismic resistance.

Most of the seismic NSE engineers take up to 10 days to supply the final Producer Statement 4 as well as up to 3-4 week notice for the site inspection. So, please plan ahead for this work to avoid the pressure at the project deadlines.

www.buildeng.nz

Case studies, News

Behind closed doors at New World Te Atatū

The transformation of a former Woolworths into New World Te Atatū called for more than a simple refurbishment. With much of the original building removed, the project combined retained structure with an entirely new supermarket fit-out, including transcritical CO₂ refrigeration, heat recovery and humidity-controlled air conditioning.