About CCCANZ

Governance

Our People

Strategic Plan

Appointments

Membership

Buying Power

Standards Library

Find A Company

Business Support

Resources

Consumers

Course Catalogue

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About Irhace

Appointments

Committees

Governance

Our People

Strategic Plan

Membership

Professional Development

Awards

Careers

Find A Professional

Education

Member Login

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About RLNZ

Our People

Governance

Privacy Policy

Strategic Plan

Approved Filler

New or Renew

Approved Filler

Approved Filler Search

Resources

Consumers

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

HVAC&R HUB

BuildNZ

Summit 2027

HVAC&R SOUTH

SouthMACH

HVAC&R WAVE

Join the Wave

Wallie Askew

How to Enter

Rules of Competition

Previous Finalists

Competition judges

WORLDSKILLS

Worldskills NZ

FIND A PROFESSIONAL

PROFESSIONAL DEVELOPMENT

CAREERS IN HVAC&R

FIND A COMPANY

BULLETINS

FACT SHEETS

GUIDELINES

COURSE CATALOGUE

REFRIGERANT RECOVERY

APPROVED FILLER SEARCH

Training Newsletter

MEDIA

INDUSTRY JOURNAL 

MEDIA KIT

INFORMATION

INDUSTRY JOURNAL

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

STANDARDS LIBRARY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

IRHACE

CAREERS IN HVAC&R

PROFESSIONAL DEVELOPMENT

COURSE CATALOGUE

CCCANZ

BUYING POWER

RESOURCES

STANDARDS

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

OUR PEOPLE

AWARDS

APPOINTMENTS

MEMBER LOGIN

MEDIA

INDUSTRY JOURNAL

INDUSTRY DIRECTORY

MEDIA KIT

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

REFRIGERANT RECOVERY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

Case study: An inner-city regeneration project

Cuba Street is known for its shopping, coffee culture, culinary delights, art galleries and street performances. Above the street, many offices take advantage of the popular location, including the Greater Wellington Regional Council. In the latter half of 2020, the council moved into the second and third floors of a newly created open-plan office space – of the city’s largest with an area of 6,000sqm. 

 

 

The building

Cuba Precinct is the result of a large regeneration project designed to embody the character of Cuba Street and its environs while providing space for ground-floor retail businesses with office and apartment accommodation above. It involved preserving and injecting life into several historic buildings as well as raising new structures above those buildings.

Designed to have a low carbon footprint and exceed the current New Building Standard, the refurbishment of the historic buildings was completed with these guiding principles in mind.

A smart air conditioning choice

The Mitsubishi Electric R32 Hybrid Variable Refrigerant Flow (HVRF) Air Conditioning System was a logical choice for the large open plan office space thanks to its superior safety features, occupier comfort levels, and lower operating and maintenance costs when compared to traditional systems using R410A refrigerant. 

Another feature of the R32 HVRF System is its ability for simultaneous heating and cooling. Heat is recovered and redistributed, negating the need for a separate heating system. It uses a unique two-pipe configuration – a reduced number of pipes which also reduces the installation cost and time.

 

Get to know the Mitsubishi Electric R32 HVRF Air Conditioning System

 

A focus on water

A significant safety feature is the use of water throughout the pipework in occupied spaces. This means that refrigerant (R32) is only used in the system between the outdoor condensers and the Hybrid Branch Controllers (HBCs) – well away from any occupied spaces. This removes the need for expensive leak detection equipment in occupied spaces, resulting in reduced maintenance costs as there is no requirement for annual leak detection checks.

 

Unique two-pipe architecture

Multi-layer composite plastic piping can be used to transport water throughout occupied spaces instead of the traditional soldered copper piping used to transport refrigerant. This feature combined with the unique two-pipe Heat Recovery System – rather than a conventional four-pipe chiller system – means less piping is installed and none of the extra controls associated with a 4-pipe system are required, amounting to significant installation cost savings.

 

 

Modular and flexible in design

The modular design and small footprint of the HVRF System along with its flexible duct layout allows airflow patterns to be arranged to suit the application, letting building owners manage a phased installation – a plus when it comes to installation budgets and their inevitable variances.

 

Efficient heating and cooling at the same time 

Outdoor units all have simultaneous heating and cooling and heat recovery. Indoor units are concealed within the ceiling space making for unobtrusive air conditioning while preserving the aesthetic of the working space and overall appearance of the room. Quiet operation is another feature of these units.

 

Year-round occupant comfort

Low noise levels (due to the use of water instead of refrigerant in the terminal fan coils among other noise-reducing features), more stable milder off-coil temperatures, the removal of draught potential from office spaces, faster defrosts, no critical refrigeration concerns and less risk to the environment and occupants all contribute to a system that provides comfort with simplified maintenance and a significant cut in long-term energy costs.

Using the system’s flexible master and individual remote controls enables efficient and economic management of airflows, heating and air conditioning levels throughout the building. 

As well as a master control, individual room units have remote controls of their own.

 

 

The logical, future-proofed solution

The cost of R410A refrigerant continues to rise rapidly as a deterrent to its use in air conditioning systems due to its high GWP (Global Warming Potential). Mitsubishi Electric’s R32 Hybrid VRF System leverages the low GWP of R32 refrigerant (about one-third that of conventional R410A refrigerant), lower refrigerant costs, a small carbon footprint and reduced running costs to provide an efficient system with built-in future-proofing able to provide high comfort levels while complying with environmental legislation – it’s the logical selection.





Header image credit: Jason Mann Photography









Case studies, News

Behind closed doors at New World Te Atatū

The transformation of a former Woolworths into New World Te Atatū called for more than a simple refurbishment. With much of the original building removed, the project combined retained structure with an entirely new supermarket fit-out, including transcritical CO₂ refrigeration, heat recovery and humidity-controlled air conditioning.