About CCCANZ

Governance

Our People

Strategic Plan

Appointments

Membership

Buying Power

Standards Library

Find A Company

Business Support

Resources

Consumers

Course Catalogue

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About Irhace

Appointments

Committees

Governance

Our People

Strategic Plan

Membership

Professional Development

Awards

Careers

Find A Professional

Education

Member Login

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About RLNZ

Our People

Governance

Privacy Policy

Strategic Plan

Approved Filler

New or Renew

Approved Filler

Approved Filler Search

Resources

Consumers

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

HVAC&R HUB

BuildNZ

Summit 2027

HVAC&R SOUTH

SouthMACH

HVAC&R WAVE

Join the Wave

Wallie Askew

How to Enter

Rules of Competition

Previous Finalists

Competition judges

WORLDSKILLS

Worldskills NZ

FIND A PROFESSIONAL

PROFESSIONAL DEVELOPMENT

CAREERS IN HVAC&R

FIND A COMPANY

BULLETINS

FACT SHEETS

GUIDELINES

COURSE CATALOGUE

REFRIGERANT RECOVERY

APPROVED FILLER SEARCH

Training Newsletter

MEDIA

INDUSTRY JOURNAL 

MEDIA KIT

INFORMATION

INDUSTRY JOURNAL

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

STANDARDS LIBRARY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

IRHACE

CAREERS IN HVAC&R

PROFESSIONAL DEVELOPMENT

COURSE CATALOGUE

CCCANZ

BUYING POWER

RESOURCES

STANDARDS

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

OUR PEOPLE

AWARDS

APPOINTMENTS

MEMBER LOGIN

MEDIA

INDUSTRY JOURNAL

INDUSTRY DIRECTORY

MEDIA KIT

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

REFRIGERANT RECOVERY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

Commercial kitchen exhaust and treatment options _ Part 2

 

This effluent is discharged to the exterior contributing to environmental pollution with detrimental effect on human health. This article examines the size of the New Zealand hospitality industry, the various cooking processes, the composition of airborne effluent and available control technologies.

 

Management of Airborne Effluents

The cooking process generates airborne particles of various sizes and composition which have been demonstrated to be detrimental to the environment and to human health. AS1668-2-2012 sets out the requirements in dealing with cooking effluents. Section 3.3.1 categorises cooking effluents as type B which are required to be removed by local exhaust (5) using a hood or similar means. The most common approach in dealing with this has been the installation of an extract system comprising of a metal hood fitted with filters installed above the cooking appliance, ducting and an extract fan discharging to the atmosphere. Although this represents the most basic and commonly applied solution, it has limitations in dealing with smaller particles and odours.

Hoods

Under AS1668.2-2012, hoods are required to be manufactured of materials deemed noncombustible in accordance with AS1530.1, such as steel or stainless steel sufficiently rigid and with smooth surfaces. Hoods are classified in seven types as shown in Table 8.

Section 3.5 of the standard provides a prescriptive method -excluding hoods type 5 and 7- to determine airflows for different types of cooking processes and hood types. Where several cooking appliances are being used, the equation relevant to the worst case is to be used for calculating airflows. In any case the airflow shall not be less than 250 l/s/ m2. Hoods type 5 and 7 are designed for lower airflows and consequently lower energy consumption, therefore, requiring more empirical calculations. Airflows for proprietary hoods type 7 designed to standards such as German VDI 2050 or DIN 18869 are acceptable.

Filtration

Baffle and the mesh type are commonly used as primary filters.

The commonly known grease filter comprises of an interwoven mesh held within a metal frame or arranged in a honeycomb pattern. Particulate matter is captured within the mesh. Common materials are aluminium and stainless steel. Baffle filters comprise of plates folded in U shape and interlocked in such a way as to impart a change of direction to the airflow. As a result of this, the larger particles impact on its walls and slide down and drain away. Baffle and mesh type filters have little effect on capturing grease vapour, gas or odours. The efficiency of these two types of grease filters is low for fine particulates. They are limited to capturing 18% to 20% of particles going through it (6). Both types rely on impact for particulate collection (44). However, these types of filters are relatively cheap and easier to clean. Comparatively, baffle type filters exhibit higher pressure drop than mesh type (19) (45).

 

More information

 

Case studies, News

Behind closed doors at New World Te Atatū

The transformation of a former Woolworths into New World Te Atatū called for more than a simple refurbishment. With much of the original building removed, the project combined retained structure with an entirely new supermarket fit-out, including transcritical CO₂ refrigeration, heat recovery and humidity-controlled air conditioning.

Competitions, News

Nominate your 2026 MVC

Competenz has launched the second round of its MVC (Most Valuable Coach) campaign to recognise the bosses, trainers and mentors who act as true game changers for our industry’s apprentices.