About CCCANZ

Governance

Our People

Strategic Plan

Appointments

Membership

Buying Power

Standards Library

Find A Company

Business Support

Resources

Consumers

Course Catalogue

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About Irhace

Appointments

Committees

Governance

Our People

Strategic Plan

Membership

Professional Development

Awards

Careers

Find A Professional

Education

Member Login

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About RLNZ

Our People

Governance

Privacy Policy

Strategic Plan

Approved Filler

New or Renew

Approved Filler

Approved Filler Search

Resources

Consumers

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

HVAC&R HUB

BuildNZ

Summit 2027

HVAC&R SOUTH

SouthMACH

HVAC&R WAVE

Join the Wave

Wallie Askew

How to Enter

Rules of Competition

Previous Finalists

Competition judges

WORLDSKILLS

Worldskills NZ

FIND A PROFESSIONAL

PROFESSIONAL DEVELOPMENT

CAREERS IN HVAC&R

FIND A COMPANY

BULLETINS

FACT SHEETS

GUIDELINES

COURSE CATALOGUE

REFRIGERANT RECOVERY

APPROVED FILLER SEARCH

Training Newsletter

MEDIA

INDUSTRY JOURNAL 

MEDIA KIT

INFORMATION

INDUSTRY JOURNAL

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

STANDARDS LIBRARY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

IRHACE

CAREERS IN HVAC&R

PROFESSIONAL DEVELOPMENT

COURSE CATALOGUE

CCCANZ

BUYING POWER

RESOURCES

STANDARDS

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

OUR PEOPLE

AWARDS

APPOINTMENTS

MEMBER LOGIN

MEDIA

INDUSTRY JOURNAL

INDUSTRY DIRECTORY

MEDIA KIT

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

REFRIGERANT RECOVERY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

Finding a heating and cooling solution Aurora Centre

Located in Christchurch within the premises of Burnside High School, The Aurora Centre is a modern, state-of-the art venue with a seating capacity of 700 – an auditorium is suited for live theatre, concerts, graduations, training seminars, presentations and many other events, which calls for a large-scale air conditioning solution to ensure a comfortable environment for all occupants.

Installed by Hartnell Coolheat, the air conditioning solution used Temperzone products to provide an integrated custom system for on-schedule, automatic space heating and cooling.

Three 70kW and two 40kW OPA rooftop package units and an Aquanex MWH900 77kW heat pump water heater were installed with a complete BMS system. These systems combine to provide around 300kW of heating and cooling and an ideal system for Christchurch conditions.

The Aquanex MWH900 heat pump water heater, including a programmable control system, pre-heats the mixed return air/fresh air to achieve 10°C on temperature to the three 70kW rooftop package units.

The MWH900 was applied to the system design for its reliability to maintain a supply water temperature of 40°C-55°C utilising an inverter compressor range of 13.3kW-91.9kW.

R32 Aquanex heat pump water heaters feature unique inverter in-line system technology, which allows for substantial efficiency gains over traditional installations. This is achieved through precise control of the heated water supply for optimised heat transfer by the application.

 

 

Each rooftop package unit has a Siemens controller fitted. The controller controls the unit and its associated return fan, motorised dampers and heating water valves, depending on the mode of operation. Each unit includes one LCD back-lit display for temperature adjustment and an after-hours function mounted on the face of the mechanical section of the switchboard.

The system provides automatic control of heating and cooling according to space demand as measured by existing space-mounted sensors. The fan speed is modulated based on the heating and cooling requirements. For heating or cooling duties below 50%, the fan speed is set to 50% (adjustable). Above 50% duty, the fan speed ramps in parallel with the heating/cooling duty. The associated spill/return air fan is controlled via a VSD to match the supply fans. The units have EC plug supply fans suitable for 10-V input from the controller.

The system features economisers for free cooling. Demand for cooling is measured by space temperature sensors which compare the outdoor air temperature to the return air temperature. If the outdoor air is cooler than the indoor air temperature by 1.5°C, fresh air and return air dampers modulate to meet the cooling demand based on the available outside air temperature. Should the space temperature not be controlled sufficiently using free cooling, the unit shall be allowed to enter cooling mode in addition to the free cooling.

For air quality control, the system includes a return air duct mounted CO2 sensor for CO2 control in conjunction with the space-mounted CO2 sensors. The fresh air damper maintains 750 ppm CO2.

The system also features a heat up mode where the system is on a start-up programme before occupancy.

Find a Company: Hartnell Coolheat, Temperzone

 

More information

 

Case studies, News

Behind closed doors at New World Te Atatū

The transformation of a former Woolworths into New World Te Atatū called for more than a simple refurbishment. With much of the original building removed, the project combined retained structure with an entirely new supermarket fit-out, including transcritical CO₂ refrigeration, heat recovery and humidity-controlled air conditioning.

Competitions, News

Nominate your 2026 MVC

Competenz has launched the second round of its MVC (Most Valuable Coach) campaign to recognise the bosses, trainers and mentors who act as true game changers for our industry’s apprentices.