About CCCANZ

Governance

Our People

Strategic Plan

Appointments

Membership

Buying Power

Standards Library

Find A Company

Business Support

Resources

Consumers

Course Catalogue

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About Irhace

Appointments

Committees

Governance

Our People

Strategic Plan

Membership

Professional Development

Awards

Careers

Find A Professional

Education

Member Login

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About RLNZ

Our People

Governance

Privacy Policy

Strategic Plan

Approved Filler

New or Renew

Approved Filler

Approved Filler Search

Resources

Consumers

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

HVAC&R HUB

BuildNZ

Summit 2027

HVAC&R SOUTH

SouthMACH

HVAC&R WAVE

Join the Wave

Wallie Askew

How to Enter

Rules of Competition

Previous Finalists

Competition judges

WORLDSKILLS

Worldskills NZ

FIND A PROFESSIONAL

PROFESSIONAL DEVELOPMENT

CAREERS IN HVAC&R

FIND A COMPANY

BULLETINS

FACT SHEETS

GUIDELINES

COURSE CATALOGUE

REFRIGERANT RECOVERY

APPROVED FILLER SEARCH

Training Newsletter

MEDIA

INDUSTRY JOURNAL 

MEDIA KIT

INFORMATION

INDUSTRY JOURNAL

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

STANDARDS LIBRARY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

IRHACE

CAREERS IN HVAC&R

PROFESSIONAL DEVELOPMENT

COURSE CATALOGUE

CCCANZ

BUYING POWER

RESOURCES

STANDARDS

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

OUR PEOPLE

AWARDS

APPOINTMENTS

MEMBER LOGIN

MEDIA

INDUSTRY JOURNAL

INDUSTRY DIRECTORY

MEDIA KIT

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

REFRIGERANT RECOVERY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

The lowdown in Hybrid Variable Refrigerant Flow (HVRF) Systems

These air conditioning systems combine the advantages of traditional VRF systems with advanced chiller technology

 

Energy efficiency is one of the major drawcards of HVRF systems, making them a popular choice as the demand for environmental responsibility grows.

Unlike conventional HVAC systems that rely solely on refrigerant lines, HVRF systems incorporate water lines.

The systems operate by replacing refrigerant with water between the hybrid branch circuit controller and the indoor units – minimising the need for expensive and ongoing leak detection servicing.

The design makes HVRF systems ideal for occupied spaces where quiet, energy-efficient, simultaneous heating and cooling is valued.

 

The benefits of Hybrid Variable Refrigerant Flow (HVRF) systems

 

Cost savings and energy efficiency

One of the main reasons for a switch to an HVRF system is for increased energy efficiency. Compared to traditional systems where energy can be wasted by heating and cooling different areas independently, HVRF systems balance this simultaneously. The use of less energy also has a positive impact on the environment.

 

No refrigerant concentration limits

By cooling and heating with water instead of refrigerant, HVRF systems can be used for most commercial buildings including hotels, offices, educational buildings, and hospitals and medical centres.

 

Flexibility

These systems also provide flexible zone control with different indoor units able to operate on heating or cooling at the same time. This is ideal for multi-tenant office buildings and hotels – individual zones can be adjusted to meet specific needs, enhancing comfort without sacrificing efficiency. However, it’s important to plan your installation – ductwork retrofitting and disruptions during installation can be experienced when adding an HVRF system to an existing building.

 

Case study highlight

An HVRF system was the right choice for a mid-sized office building in central Christchurch, which was recently installed by Beattie Air. The transition from a conventional HVAC system to a Mitsubishi Electric HVRF system was made to reduce operating costs and temperature inconsistencies.

 

The results

• A 30 per cent reduction in energy usage was seen within the first year.

• There was a 50 per cent drop in complaints about temperature inconsistencies.

• Improved system reliability paired with fewer mechanical issues has decreased maintenance costs.

• The building’s overall safety has been improved thanks to the reduced use of high-pressure refrigerant lines.

Case studies, News

Behind closed doors at New World Te Atatū

The transformation of a former Woolworths into New World Te Atatū called for more than a simple refurbishment. With much of the original building removed, the project combined retained structure with an entirely new supermarket fit-out, including transcritical CO₂ refrigeration, heat recovery and humidity-controlled air conditioning.

Competitions, News

Nominate your 2026 MVC

Competenz has launched the second round of its MVC (Most Valuable Coach) campaign to recognise the bosses, trainers and mentors who act as true game changers for our industry’s apprentices.