About CCCANZ

Governance

Our People

Strategic Plan

Appointments

Membership

Buying Power

Standards Library

Find A Company

Business Support

Resources

Consumers

Course Catalogue

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About Irhace

Appointments

Committees

Governance

Our People

Strategic Plan

Membership

Professional Development

Awards

Careers

Find A Professional

Education

Member Login

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

About RLNZ

Our People

Governance

Privacy Policy

Strategic Plan

Approved Filler

New or Renew

Approved Filler

Approved Filler Search

Resources

Consumers

Refrigerant Recovery

Training Newsletter

What's On

HVAC&R HUB

HVAC&R South

Wallie Askew

Worldskills

HVAC&R HUB

BuildNZ

Summit 2027

HVAC&R SOUTH

SouthMACH

HVAC&R WAVE

Join the Wave

Wallie Askew

How to Enter

Rules of Competition

Previous Finalists

Competition judges

WORLDSKILLS

Worldskills NZ

FIND A PROFESSIONAL

PROFESSIONAL DEVELOPMENT

CAREERS IN HVAC&R

FIND A COMPANY

BULLETINS

FACT SHEETS

GUIDELINES

COURSE CATALOGUE

REFRIGERANT RECOVERY

APPROVED FILLER SEARCH

Training Newsletter

MEDIA

INDUSTRY JOURNAL 

MEDIA KIT

INFORMATION

INDUSTRY JOURNAL

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

STANDARDS LIBRARY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

IRHACE

CAREERS IN HVAC&R

PROFESSIONAL DEVELOPMENT

COURSE CATALOGUE

CCCANZ

BUYING POWER

RESOURCES

STANDARDS

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

OUR PEOPLE

AWARDS

APPOINTMENTS

MEMBER LOGIN

MEDIA

INDUSTRY JOURNAL

INDUSTRY DIRECTORY

MEDIA KIT

TRAINING NEWSLETTER

RESOURCES

CONSUMERS

COURSE CATALOGUE

PROFESSIONAL DEVELOPMENT

REFRIGERANT RECOVERY

MEMBERSHIP

COMPANY AFFILIATE

COMPANY MEMBER

INDIVIDUAL MEMBER

New ventilation rules take effect: What changes after G4/AS1?

New ventilation rules take effect: What changes after G4/AS1?

The G4/AS1 transition ended on July 31. Now New Zealand’s HVAC&R industry must adapt to the latest ventilation compliance pathway.

New Zealand’s HVAC&R sector has reached another important milestone in the evolution of building ventilation standards. For contractors, designers and consenting authorities, the end of the G4/AS1 transition is more than an administrative update: it signals a renewed focus on ventilation performance, documentation and compliance.

As of August 1, 2026, building consent applications can no longer rely on the Fourth Edition of G4/AS1. Instead, projects seeking to follow an Acceptable Solution pathway must use the Fifth Edition of G4/AS1, which came into effect on July 28, 2025, after a 12-month transition period.

For an industry already navigating changing refrigerant technologies, energy efficiency requirements and growing expectations around indoor air quality, the deadline serves as another reminder that ventilation is becoming an increasingly critical part of building performance.

More than a document update

Clause G4 of the New Zealand Building Code has always required occupied spaces to be provided with adequate ventilation consistent with their intended use and occupancy. The Acceptable Solution provides one of the recognised pathways for demonstrating compliance with those performance requirements.

While many of the fundamental ventilation principles remain familiar, the Fifth Edition has been substantially modernised. Rather than simply amending the previous document, MBIE has restructured G4/AS1 into a standalone publication with clearer language, updated terminology and improved organisation.

The revised document covers natural, mechanical and hybrid ventilation systems across residential and commercial buildings, while also incorporating provisions for gas-fuel appliances and flue locations. It references current New Zealand and Australian standards and now works alongside the new Building Product Specifications framework introduced under the Building Act.

For designers and contractors, the changes provide greater clarity, but they also require familiarity with the new document structure and referenced specifications.

Why it matters to HVAC&R

Ventilation has become one of the fastest-evolving areas of building services, largely in part to the increased focus on indoor air quality following the Covid-19 pandemic, alongside increasing expectations around occupant wellbeing. The push towards more energy-efficient buildings has also elevated ventilation from a background service to
a key component of overall building performance.

Mechanical ventilation systems are now expected to balance several competing objectives. They must provide sufficient outdoor air to maintain healthy indoor environments, manage moisture and contaminants, integrate with increasingly airtight building envelopes, and minimise unnecessary energy consumption.

For HVAC&R professionals, achieving that balance relies on careful system selection, accurate commissioning and thorough documentation.

The updated G4/AS1 reinforces this integrated approach, recognising that ventilation is no longer simply about meeting minimum air change rates but about delivering measurable building performance.

A broader shift in compliance

The end of the transition also reflects a wider direction across New Zealand’s building regulatory framework.

Over recent years, MBIE has progressively updated numerous Acceptable Solutions and Verification Methods, introducing clearer compliance pathways, greater alignment with current standards and improved product specification requirements.

Adapting to the change

All projects submitted for building consent must now reference the Fifth Edition where using the Acceptable Solution pathway. Existing projects lodged before that date can continue under the previous edition where applicable during the consent process.

Design consultants, mechanical engineers, contractors and suppliers should ensure specification templates, design references and internal quality systems have all been updated to reflect the current requirements.

What’s ahead

As buildings become more energy efficient and occupant expectations continue to rise, ventilation will increasingly influence comfort, health, operational performance and overall building value. Meeting the latest version of G4/AS1 is therefore not simply about satisfying a regulatory requirement. It’s about delivering buildings that perform as intended throughout their lifecycle – both a challenge and an opportunity for the entire industry.

Case studies, News

Behind closed doors at New World Te Atatū

The transformation of a former Woolworths into New World Te Atatū called for more than a simple refurbishment. With much of the original building removed, the project combined retained structure with an entirely new supermarket fit-out, including transcritical CO₂ refrigeration, heat recovery and humidity-controlled air conditioning.

Competitions, News

Nominate your 2026 MVC

Competenz has launched the second round of its MVC (Most Valuable Coach) campaign to recognise the bosses, trainers and mentors who act as true game changers for our industry’s apprentices.