What the granny flat exemption means for the HVAC industry
It’s now easier for small, standalone dwellings to be built without a building consent. It reduces red tape for homeowners and is aimed at increasing housing supply, but it places greater responsibility on building professionals, including those working in HVAC.
From January 2026, New Zealand’s new granny flat building consent exemption will make it easier to build small standalone dwellings of up to 70sqm without a building consent. While the policy is aimed at increasing housing supply and reducing red tape, it places greater responsibility on building professionals, including those working in HVAC.
Importantly, no consent doesn’t mean no compliance. For heating, ventilation and energy professionals, this exemption is not a regulatory shortcut. It’s a shift in accountability.
Ventilation requirements
Granny flats must comply with Building Code Clause G4 – Ventilation, ensuring adequate ventilation for occupant health and moisture control. This directly impacts:
- Mechanical ventilation design;
- Bathroom and kitchen extraction systems; and
- Whole-of-dwelling ventilation strategies.
Exempt builds aren’t inspected, so ventilation failures may only surface later. This can present as moisture damage and mould, so getting the correct system selection and airflow design right from the start is vital.
Heating systems
Under the exemption, only gas or electric heaters are allowed. Solid fuel heaters such as wood burners are not permitted under the exemption and would trigger the need for a building consent.
This means homeowners, designers, builders and installation technicians need to be mindful of heat pump selection, electric resistance heaters and gas heating system design and compliance.
Energy efficiency
Granny flats must comply with Building Code Clause H1 – Energy Efficiency. Insulation coordination with heating and ventilation design plays into this, alongside the efficiency of heating systems and the overall thermal performance of the dwelling.
Heating systems must be appropriate for:
- The dwelling size;
- Insulation levels;
- Climate zone; and
- Occupant use.
Gas installations
Where gas is used, the granny flat must have an independent gas supply and all gasfitting must be carried out by a licensed gasfitter. Gas certificates of compliance and gas safety certificates must still be provided at completion.
Water heating
Under the exemption, uncontrolled water heating is prohibited. This affects hot water system selection and integration with HVAC-related energy systems.
HVAC professionals involved in hot water or energy-efficient systems should ensure solutions meet both Building Code requirements and the exemption conditions.
Documentation and certification requirements
HVAC professionals may be responsible for the following documentation when working on a
stand-alone dwelling:
- Electrical safety certificates (for heat pumps, ventilation systems, controls);
- Gas safety certificates; and
- Records of Work and certificates to council.
Poor HVAC design or installation can invalidate the exemption.
Increased professional responsibility
The granny flat exemption creates opportunity, but it also comes with risk: professionals in our sector will be further relied upon. Your work can later demonstrate that the dwelling was lawfully built, systems were installed by licensed professionals, and that the building complies with the Building Code. Incomplete documentation or non-compliant installations can place liability on both the installer and the homeowner.
For all projects, there needs to be early involvement in design discussions, clear documentation and commissioning records, confirmation that system choices don’t invalidate the exemption, and education for clients about system limitations.
Standards haven’t been reduced; the responsibility has simply been moved closer to the industry.